Latest news
HardwareVertiv

Vertiv Expands Its 800 VDC Portfolio Across Racks, AI Pods and Data Halls

On November 17, 2026, Vertiv announced an expansion of its 800 VDC portfolio to cover rack, AI compute pod and data hall levels. The company says the rack architecture can preserve existing AC infrastructure.

Contemporary data center with server racks and modular outdoor power infrastructureAI image
Representative image, generated with AI.Image: 3dsınıfı / FCA AI

In brief

  1. Vertiv’s expanded 800 VDC portfolio includes three architectural options for rack, AI compute pod and data hall levels.
  2. According to the company, PowerDirect 5000 can be configured for up to 800 kW and provides 800 VDC or ±400 VDC output from a 480 VAC input.
  3. Vertiv presents PowerDirect 9000 as a 1.5 MW solution and PowerNexus MV SST as a 5 MW solution.
  4. Vertiv is showcasing its portfolio at SC26, held November 15–20, 2026; pilot and technical validation work is ongoing.

On November 17, 2026, Vertiv announced an expansion of its 800 VDC power portfolio for AI data centers. According to the company, the expanded portfolio offers different power distribution architectures at the IT rack, AI compute pod and data hall levels. Vertiv is showcasing its portfolio at the SC26 International Conference for High Performance Computing, Networking, Storage, and Analysis, held November 15–20.

Rack-level power distribution

The rack-scale solution, PowerDirect 5000, is positioned alongside the IT rack. According to Vertiv, the system can be configured for up to 800 kW; it takes the facility’s 480 VAC supply and delivers 800 VDC or ±400 VDC output. The power rack contains 30 hot-swappable 30 kW power supplies. Its integrated battery backup unit is designed to provide at least 50 seconds of runtime.

PowerDirect 3000 is a 1U, 90 kW DC-DC converter installed inside the compute rack. According to the manufacturer, it converts 800 VDC to 54 VDC for compute trays, with peak efficiency of up to 98.5%. Vertiv says that moving power conversion and energy storage outside the IT rack in this architecture can free up 8 to 16 rack units for compute hardware. The option to preserve existing AC infrastructure is also highlighted specifically for this rack solution.

AI compute pod and data hall options

PowerDirect 9000 is presented as a 1.5 MW power center. According to Vertiv, the system converts 480 VAC to 800 VDC to supply a row or pod, scaling in 60 kW increments. In the pod architecture, the EnergyCore Li5 800 VDC battery cabinet connects to the DC bus to provide 200 kW of continuous backup power. The company says active current sharing supports parallel operation of up to six cabinets.

The data hall-scale PowerNexus MV SST is a 5 MW solid-state transformer. The manufacturer says it converts medium-voltage AC to 800 VDC in a single conversion stage and delivers AC-DC efficiency of up to 98%. Its outdoor, liquid-cooled, containerized design is said to be capable of independently supporting Vertiv’s 4.8 MW SuperPod reference architecture. External energy storage can also help manage power fluctuations when connected to the 800 VDC bus through a DC-DC converter.

Implications for architecture and visualization workflows

These options address the placement of power equipment and technical space requirements in data center projects in different ways. In the rack solution, some power components are moved outside the IT rack, while the pod approach centralizes conversion at the front of the row. The data hall solution, meanwhile, is designed to locate power conversion equipment outdoors. As a result, architecture and interior design teams may need to assess rack layouts, technical spaces and outdoor area use in coordination with project engineers.

For archviz teams, clarifying early on which scale the power architecture is planned for can help establish accurate layout scenarios. The announcement does not say that the different solutions will apply in the same way to existing facilities: the option to preserve AC infrastructure is described specifically for the rack architecture, while the company notes more broadly that AC and DC systems can coexist. Vertiv also lists safety features such as touch-safe busbars, high-voltage insulation, ground fault detection and arc flash prevention. Pricing, licensing model and general availability timeline have not been announced.

Pilot programs underway

Vertiv says pilot programs, technical validation activities and co-development efforts are ongoing based on customer requirements. The company does not foresee a single architecture or timeline for the transition to 800 VDC, given the differences between facilities and business models. This suggests that the announced solutions should be assessed alongside facility conditions and power requirements when making implementation decisions.

Sources

1 source
H
HPCwirehpcwire.com/off-the-wire/vertiv-advances-800-vdc-power-architectures-to-support-growing-ai-data-center-demands
Summary

Source texts are not republished; short quotes are marked, everything else is our own summary and commentary.

3dsınıfı’s take
3dEditor’s assessment

Vertiv’s announcement shows that power distribution for high-density AI infrastructure cannot be considered separately from building and site planning. Because rack, pod and data hall solutions offer different component and layout choices, those upgrading existing facilities and those planning new ones need to assess their requirements separately.

For offices and visualization teams in Turkey, existing electrical infrastructure, technical space requirements and backup strategy should be reviewed before focusing on the announced capacity figures. Pricing and licensing terms have not been disclosed, and pilot and validation work is still underway. For this reason, waiting for product terms to become clear is important when making implementation and investment decisions and assessing compatibility risks.

Frequently asked questions

Which installation levels does Vertiv’s 800 VDC portfolio cover?

The portfolio covers three architectural options at the rack, AI compute pod and data hall levels. Vertiv positions these options for different facility and workload requirements.

What are the capacity and input voltage of PowerDirect 5000?

According to Vertiv, PowerDirect 5000 can be configured for up to 800 kW and takes a 480 VAC input. It can provide 800 VDC or ±400 VDC output.

Has Vertiv announced pricing for its 800 VDC systems?

The announcement does not provide pricing or licensing model details. The company says pilot and technical validation work tailored to customer needs is ongoing.

Comments and the forum are in Turkish.Join the discussion
+

Related news